4.1.2. Automatic connection check

Automatic Connection Check

The "Automatic Connection Check" function automatically detects when a placed support is not correctly connected to a pipe. This ensures that planning errors are identified immediately and model quality is maintained.

Prerequisites

Step-by-Step Instructions

  1. Place support: Select a support from the pipe spec and place it on a free surface or at the desired position in the model area.
  2. Automatic Detection: The system automatically checks in the background whether a valid connection exists between the support and the corresponding pipe. If no connection is detected, the system colors the support red as a warning.

    Expected result: Incorrectly placed or loose supports are immediately highlighted visually.

  3. Perform Correction: Reposition the support so that it snaps correctly onto the pipe.

    Expected result: As soon as the correct connection is established, the red marking disappears automatically.

Important Notes

Troubleshooting