8.3.6. Turbo tools do not place components
On this page
In this article, you will learn why the TurboTools may not suggest or place components and how you can fix this behavior. A correctly configured work environment is a prerequisite for the error-free function of the automation features.
Prerequisites
- An open AutoCAD Plant 3D project.
- Installed and licensed TurboTools.
Step-by-step instructions
- Actively select spec: In the Plant 3D user interface, select the desired Spec that contains the required components.
- Check spec: Ensure that the active Spec actually contains the relevant elements (e.g., supports or valves). If necessary, expand the spec using the Spec Editor.
- Run TurboTools again: Restart the TurboTools only after successfully selecting the spec.
Expected result: The matching components from the active spec are now displayed in the TurboTools tool selection and can be placed in the model.
Important notes
- TurboTools check the active spec stored in the project to filter available components.
- In projects with many specs, use a clear naming convention to avoid confusion.
- If the tool selection remains empty, this is almost always an indication of a missing or incomplete spec.
Troubleshooting
If no components appear despite an active spec:
- Check whether the components are available in the spec for the current Size.
- Ensure that the spec is correctly linked in the Project Manager and is not read-only or corrupted.