Skip to Content

4.1.1. Automatic nominal diameter check

Updated on 07/09/2026

On this page

    Automatic nominal diameter check

    The Automatic nominal diameter check function automatically checks, when placing and modifying pipe supports, whether the outside diameter of the pipe lies within the permissible clamping range of the support. This way, incorrect combinations are already detected during modeling and highlighted visually.

    Prerequisites

    • The check only applies to SuCri supports for which a clamping range is stored (parameter od_max). Supports without this parameter are not checked.
    • The support must be connected to a pipe that has a defined outside diameter (OD).

    Step-by-step guide

    1. Select support: Select the desired support from the pipe spec (e.g. a pipe shoe DN 100 with a clamping range of 109 to 115 mm).
    2. Placement: Place the support at the intended position on the pipe in the model.
    3. Automatic check: In the background, SuCri checks whether the outside diameter of the pipe falls within the stored clamping range of the support. If it lies within the range, the support adopts the outside diameter of the pipe.
    4. Messages: If the outside diameter lies outside the clamping range, SuCri writes the message Rohr-OD liegt nicht im Bereich der Halterung to the command line. In addition, a notification window appears with the text Pipe OD not in support range!! (this text is in English in the German interface as well).
    5. Confirmation: Click the OK button to close the notification window.

    Expected result: The support is placed in the model but displayed in red to indicate the dimensional deviation visually. As soon as the support belongs to a matching pipe again, it gets its normal color back.

    Important notes

    • Notification window only once: The notification window appears once per newly placed support, not with every further modification. The message in the command line, on the other hand, appears with every check.
    • Bulk actions: When replacing supports (Replace) and when switching profiles (Switch Profile), SuCri suppresses the notification window. The red coloring and the command line message remain.
    • No lock: The warning serves as an important notice but is not a hard lock; placement is still technically possible.
    • Documentation: If special solutions are necessary, the visual deviation (red display) should be explicitly documented in the project history.
    • Data maintenance: Make sure that pipe and support data (OD and clamping ranges) are always maintained correctly in the catalogs.

    Troubleshooting

    • The warning appears despite correct dimensions: Check the values for the outside diameter and the clamping ranges stored in the catalog. If necessary, check the CAD family for incorrect parameters.
    • Warning with special dimensions: Since placement is still possible, you can set the support. Mark this case internally as an approved special solution.
    • No check, no red display: Check whether the support is connected to the pipe and whether a clamping range (od_max) is stored for it.
    • Deactivating the function: Turning off the check via the settings is currently not provided.

    Related articles

    Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.

    Still a question open?

    Write to us, we answer within 24 hours on business days.

    Request a consultation