Skip to Content
SuCri® Knowledge Base 7. Frequently asked questions about SuCri 7.5. Module 3 (ADVS) 7.5.8. Where can I see which Connections are available?

7.5.8. Where can I see which Connections are available?

Updated on 10/11/2026

On this page

    In this article you will learn how to see in Advance Steel which connections SuCri Module 3 offers for your profiles. In SuCri, "Connections" means steel connections, that is, joints between structural steel profiles. They are not software interfaces.

    Prerequisites

    • SuCri Module 3 is installed and licensed in Advance Steel.
    • The profiles you want to connect exist in the model.

    Displaying available connections for your profiles

    SuCri always shows the matching connections for the specifically selected profiles. To do this, start one of the connection commands, either via the Connections group of the Module 3 SuCri tool palette or via the connection dialog (SuCri3ShowSelectConnection):

    Command

    Button

    Type

    Situation

    SuCri3ConnectCollision

    Collision

    T

    A profile butts against a main profile. Select the main profile first, then the profile to be connected.

    SuCri3ConnectFreeEnd

    Free end

    I

    Free end of a single profile.

    SuCri3ConnectCrossing

    Crossing

    X

    Two crossing profiles. Select the main profile first, then the crossing profile.

    SuCri3ConnectJoint

    Joint

    V

    Two profiles meet end to end.

    SuCri3Connect3Corner

    3 corner

    Y

    Three profiles meet in one node. Select the main profile first, then the other two.

    SuCri3Connect4Corner

    4 corner

    K

    Four profiles meet in one node. Select the main profile first, then the other three.

    SuCri3ConnectParallel

    Parallel

    P

    Two parallel profiles. Select the main profile first, then the parallel profile.

    After the profiles have been selected, SuCri lists the connections that are stored in the active manufacturer's catalog for this profile combination.

    Complete overview of all connections

    1. Open the Module 3 SuCri dashboard and switch to the Documentation section.
    2. On the SuCri tab, under Index Sheet, click Open.
      Expected result: The index data sheets with all connections open in the browser.
    3. On the Manufacturer tab you will also find the data sheets of the respective manufacturer.

    Important notes

    • Manufacturer-dependent: Which connections are offered depends on the catalog of the manufacturer extension used (Extension).
    • Profile-dependent: Only connections that are stored for the selected profiles are offered. For unsupported profiles, see 7.5.7. How can I work with profiles that are not supported.
    • Check: With the command SuCri3ValidateConnections ("Validate connections") you check whether placed connections still match the profiles.

    Troubleshooting

    • No connection is offered: Check the selection order (main profile first) and whether the profile is supported in the manufacturer catalog.
    • New or changed catalog data does not appear: Run SuCri3ReloadData ("Reload Vendor Data").

    Related articles

    Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.

    Still a question open?

    Write to us, we answer within 24 hours on business days.

    Request a consultation