Here you will learn how SuCri Module 4 handles Advance Steel steelwork located in a Plant 3D model. In the current version, Module 4 recognizes Advance Steel beams as profiles and includes them in the dimensioning. However, they are not included in the Plant 3D bill of materials.

Prerequisites

Your Plant 3D model contains beams from Advance Steel, and you create an ortho drawing with SuCri Module 4.

How Module 4 behaves

  • Dimensioning: Advance Steel beams are treated as profiles, like Plant 3D steel profiles, and are taken into account in automatic dimensioning.
  • Attached classes: The setting "Attached classes shown vertically" (ShowAttachVertical) contains both Plant 3D steel profiles and Advance Steel beams by default.
  • Bill of materials: The bill of materials of the ortho drawing is generated from the Plant 3D project data. Advance Steel beams are not contained there and therefore do not appear in the bill of materials.

Step-by-step guide

  1. Make sure that you are using a current SuCri version.
  2. Create the drawing with SuCri Module 4 or update existing views with SuCri4PlantOrthoUpdateAllView.
  3. Check the result: the Advance Steel beams are displayed and dimensioned but do not appear in the bill of materials.

Important notes

  • Older versions: In older SuCri versions, Advance Steel beams were not dimensioned. In this case, update SuCri and then the views.
  • Bill of materials for the steelwork: You create bills of materials and fabrication documents for the Advance Steel steelwork directly in Advance Steel, which remains the authoritative system for fabrication, connections and holes.

Troubleshooting

  • Advance Steel beams are not dimensioned: Check your SuCri version and update the views. Also check the dimensioning settings on the "Dimensions" tab of the Module 4 settings.
  • Beams are missing from the bill of materials: This is due to the system. Create the bill of materials for the steelwork in Advance Steel.

Related articles