4.1.5. Dynamic clamping systems

Updated on 10/11/2026

On this page

    Dynamic clamping systems

    The Dynamic clamping systems function allows you to precisely adjust and move clamping systems. This allows the position, clamping range and index of a clamping system to be flexibly matched to the geometry of the support.

    Other language: This video also has a German audio track. Click the YouTube logo in the video and choose your language on YouTube under Settings (gear icon) → Audio track.

    Prerequisites

    • The support used must be configured for the use of clamping systems.
    • An up-to-date index sheet for the clamp specifications must be available.

    Step-by-step instructions

    1. Select the support: Select the support or component to which you want to assign a clamping system.
    2. Open the properties: Open the properties of the support via the context menu or the property editor.
    3. Assign the clamping system: In the parameter field CLAMP or Klemme, enter the desired clamp index according to the specification or the index sheet.
    4. Adjust the clamping range: Arrows now appear in the model. Use the outer arrow to set the clamping range. Drag the arrow manually to adjust the range.
    5. Position the clamping system: With the middle arrow you can move the entire clamp along the axis if the position needs to be offset.
    6. Complete the adjustment: As soon as the clamp is correctly matched to the geometry, the process is complete.

    Expected result: The clamping system is geometrically correctly positioned on the component and meets the technical specifications.

    Important notes

    • Check the specification: Make sure that the index sheet used is up to date and exactly matches the clamp specification.
    • Collision check: After each adjustment, check visually whether the clamp is seated correctly and does not cause collisions with other components.
    • Readjustment: After major changes to the model geometry, a subsequent readjustment of the clamping system may be necessary.
    • Documentation: Document special cases or deliberate deviations from the standard.

    Troubleshooting

    • The clamp cannot be moved:

      • Check whether the selected component technically supports dynamic clamping systems.
      • Make sure that the parameter CLAMP exists in the editor and is not read-only.
      • Check whether existing geometries or locked layers restrict the movement.
    • Deactivating the function: Deactivation is generally not necessary, as the function serves quality assurance. If switching it off is absolutely necessary for the project, this must be noted in the project documentation.