Skip to Content
SuCri® Knowledge Base 8. Troubleshooting in SuCri 8.5. Module 3 (ADVS) 8.5.5. Primary supports and clamping systems are missing in the Advance Steel bill of materials

8.5.5. Primary supports and clamping systems are missing in the Advance Steel bill of materials

Updated on 07/09/2026

On this page

    This article explains why primary supports and clamping systems deliberately do not appear in the Advance Steel bill of materials and how to evaluate them correctly. This is important to avoid errors in material ordering caused by double counting.

    Prerequisites

    • Modeling of the primary supports and clamping systems in AutoCAD Plant 3D.
    • Use of the SuCri modules for data exchange and MTO creation.

    Step-by-step instructions

    1. Correct evaluation of the components

    Use the module intended for each component group to obtain a consistent bill of materials:

    • Evaluate primary supports and clamping systems exclusively via SuCri Module 2 (MTO) in Plant 3D.
    • The complete take-off of the secondary steelwork, on the other hand, is done directly in Advance Steel.

    Result: You receive two clearly separated lists without overlaps.

    2. Visualization in Advance Steel

    Use the import function in Advance Steel exclusively to complete your drawings graphically:

    • Import the supports to display primary supports in relation to the steel construction on the drawing.
    • Use the imported objects for dimensioning and for creating labels.

    Result: The assembly drawings are complete and correctly dimensioned, while the bill of materials (BOM) remains clean.

    Important notes

    • Deactivation: Primary supports and clamping systems are deliberately deactivated in the Advance Steel BOM (bill of materials) to prevent double counting.
    • Purpose of the import function: The import function in Advance Steel serves visualization and drawing creation, not bill of materials generation.
    • Data consistency: Make sure that changes to supports are primarily made in the Plant 3D model.

    Troubleshooting

    If components are missing from your lists or appear twice, check the following points:

    • Double counting: Make sure that no secondary steel components that already exist in Advance Steel have been recorded manually in Plant 3D.
    • MTO settings: In SuCri Module 2, check whether all required support classes have been selected for the export.

    Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.

    Still a question open?

    Write to us, we answer within 24 hours on business days.

    Request a consultation