In this article you will learn how to fix display problems where profiles in Advance Steel are only shown as triangles. This incorrect geometry occurs when Advance Steel does not know the profile definitions of the profile system. The SuCri patcher enters these definitions into the Advance Steel databases.

Prerequisites

  • You have local administrator rights on your system.
  • SuCri Module 3 for Advance Steel is installed.
  • Advance Steel is closed during the patch process.

Step-by-step guide

  1. Locate the executable file of the SuCri patcher (see Storage location of the SuCri patcher).
  2. Run the SuCri patcher via right-click as administrator. This ensures that the profile information can be written to the internal databases of Advance Steel.
  3. Answer the patcher's prompts: first the language of your Advance Steel installation (DEU or INT), then the Advance Steel version and finally the manufacturer of the profile system. The patcher works in the data directory C:\ProgramData\Autodesk\Advance Steel <Version>\<Sprache> (<Sprache> = language).
  4. Select the option 5 - Patch Everything. It writes both the common data (like option 1) and the profiles, mappings and templates of the selected manufacturer. Wait for the message "Patch completed successfully!".
  5. Restart Advance Steel and open your project.
    Expected result: The profiles are now displayed in their actual geometry instead of as triangles.

Important notes

  • New installations: Run the SuCri patcher again after every update or new installation of Advance Steel.
  • Multiple versions or languages: The patcher always processes exactly the selected combination of language and version. Repeat the process for every installed Advance Steel version you work with.
  • Database integrity: The patcher is mandatory so that Advance Steel recognizes the SuCri profile definitions.

Troubleshooting

  • Problem: The patcher reports "Path to DB not found".
    Solution: No directory exists under C:\ProgramData\Autodesk\ for the selected combination of language and version. Check your selection.
  • Problem: The patcher reports "Resourcepath not found".
    Solution: The resources of the selected version are not located with the patcher. Use the patcher from the current SuCri installation (see After the new version I can no longer find the patcher).
  • Problem: Triangles still appear despite the patch process.
    Solution: Check whether you have selected the language and version matching your installation and whether you have write permissions for the directory C:\ProgramData\Autodesk\Advance Steel <Version>.