Skip to Content

8.3.3. Dynamic properties are reset

Updated on 10/11/2026

On this page

    Learn how to avoid data loss with dynamic component properties in Plant 3D and how to restore lost values. SuCri writes dynamic properties to the supports with the command SuCri2DynamicProperties. A SpecUpdate (comparison with the pipe spec) in Plant 3D can overwrite these values.

    Prerequisites

    • Use of AutoCAD Plant 3D within a project.
    • Use of dynamic properties that were written by SuCri.

    Step-by-step instructions

    To prevent or undo the loss of data, please follow these instructions:

    1. Check before the SpecUpdate: Before you perform a SpecUpdate, check whether dynamic properties are used in the current project that are not defined in the pipe spec.
      Result: You avoid unintentional overwriting of data.
    2. Store properties in the pipe spec: Transfer recurring property values to the corresponding pipe spec. To do this, open the Spec Editor and complete the fields.
      Result: The values remain consistent even after an update.
    3. Write dynamic properties again: If an update has already been performed and properties have been lost, run SuCri2DynamicProperties again (tool palette: Dyn. properties). In the dialog, select the affected drawings.
      Result: SuCri rewrites the dynamic properties of the supports in the selected drawings.

    Important notes

    • Do not confuse: The command SuCri2UpdatePropertiesFromSpec (button Spec Properties) deliberately resets the support properties to the spec. Do not use it to restore lost dynamic properties.
    • Awareness: Inform your project team that a SpecUpdate compares the components with the default definitions of the pipe spec and overwrites deviating values.
    • Process control: Define clear project standards for who may perform a SpecUpdate and when, and run SuCri2DynamicProperties afterwards.
    • Locked drawings: Locked drawings are grayed out in the dialog and are not updated.

    Troubleshooting

    Problem: After an update, components suddenly show default values again instead of the adjusted properties.

    • Solution 1: Run SuCri2DynamicProperties again for the affected drawings.
    • Solution 2: Check whether the SpecUpdate was absolutely necessary for the affected components and, if necessary, undo the change using a backup copy.
    • Solution 3: If the data of the clamping system is not written despite a matching spec row, check the setting "Always apply rules (ignore matching spec rows)" in the Module 2 settings, "Dynamic properties" group.

    Related articles

    Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.

    Still a question open?

    Write to us, we answer within 24 hours on business days.

    Request a consultation