4.2.42. Convert selected profiles to spec profile (SuCri2SwitchProfileStructure)
On this page
Overview
Switch Profile converts steel profiles from Plant 3D structural steel into pipe spec profiles, for a selection, the current drawing or selected drawings of the project. In addition to the classic structural steel catalog, IntegaDesign also offers the manufacturer profiles as pipe spec profiles; this command replaces a structural steel profile with the matching profile from the current pipe spec.
Advantage: The steel profiles also appear, for example, in the piping bill of materials of the ortho.
The explicit recommendation is to use the profiles from the classic structural steel catalog as a rule. The pipe spec variant is intended for cases in which structural steel and piping are to be evaluated together.
Where can I find the function?
SuCri tool palette > group Extras (collapsed) > Switch Profile. You open the palette in the dashboard (tab "SuCri" > panel "Module 2" > manufacturer button) via the pin icon in the title bar ("Pin to tool palette"). Alternatively, call the command SuCri2SwitchProfileStructure via the command line.
Plant 3D™ command
| Property | Value |
|---|---|
| Command | SuCri2SwitchProfileStructure |
| Tool palette | Extras > Switch Profile |
| Keyboard shortcut | No default shortcut |
Video
How it works in detail
- Start Switch Profile: In the tool palette under Extras, click Switch Profile or enter
SuCri2SwitchProfileStructure. The Select Drawings dialog opens. - Choose the scope:
- Current Drawing: Without any further selection, all profiles of the drawing are switched ("Nothing selected = whole drawing is switched."). With Select objects... you select individual profiles; the command line then asks "Please select Structure to switch <Enter = whole drawing>".
- Project: Mark the desired project drawings. SuCri opens, switches and saves each drawing and closes it again if it was not open before.
- Delete old profiles? SuCri asks "Delete the old structure profiles after switching?". With Yes the original structural steel profiles are removed, with No they are kept in addition. With the drawing source Project, the question appears once before the start for all drawings.
- Result: For each profile, SuCri searches the current pipe spec for a part of the same size and reports "Item found in current spect: …" in the command line. With the drawing source Project, SuCri then offers an Excel report of the switched profiles for saving (file name beginning with "Profile Switched Project").
Profiles from the pipe spec can be changed dynamically in length on both sides as usual. The length change is automatically transferred to the Length property, so that the material take-off is correct.
Via the properties, additional details can be switched on and off, for example for customer presentations or renderings. However, these details cost performance, the hole function particularly noticeably.
Application examples
Example 1: Converting individual profiles
In a structure, only a few beams are to be evaluated together with the piping. You choose Current Drawing, click Select objects..., select exactly these profiles and switch them; the rest of the structural steel remains in the classic catalog.
Example 2: Display for a presentation
For a rendering, details such as drill holes are to be visible. You switch them on for the switched profiles via the properties and switch them off again afterwards, so that the working speed in the model is maintained.
Tips and best practices
- When in doubt, the classic structural steel catalog: This is the explicit recommendation. The pipe spec profiles are the special case, not the normal case.
- Details cost performance: The hole function in particular has a noticeable effect. Leave it switched off for daily work.
- Whole drawing or project: Without an object selection, the command switches all profiles of the current drawing; with the drawing source Project, all profiles of the selected drawings.
- Notification window suppressed: During the switch, SuCri does not show a notification window of the nominal diameter check.
Troubleshooting
- "Reader can't find any components with spec …, size: …": The profile is not contained in the current pipe spec. Select a pipe spec that contains the profile, or add it there.
- "No structure found to switch.": The drawing or selection does not contain any Plant 3D steel profiles.
- "No structure profile was switched.": No matching part was found in the pipe spec for any of the profiles.
- "… cannot be converted. Make sure that the latest Python scripts are installed": Update the SuCri installation.
- "Cannot open …, skipped.": The project drawing is locked or missing. Have other users close it and repeat the process.
Related articles
- Spec Properties, resets the properties of the supports according to the pipe spec.
- Steel construction profiles from the pipe class, explains the pipe spec profiles.
Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.