Prerequisites

  • SuCri Module 3 is installed and licensed.
  • The manufacturer extension whose components you want to use is active.

The connection types

There is a separate command for each installation situation. You will find the commands in the Connections group of the SuCri tool palette and in the connection dialog (SuCri3ShowSelectConnection).

Command

Button

Type

Situation

SuCri3ConnectCollision

Collision

T

A profile butts against a main profile. Select the main profile first, then the profile to be connected.

SuCri3ConnectFreeEnd

Free end

I

Free end of a single profile.

SuCri3ConnectCrossing

Crossing

X

Two crossing profiles. Select the main profile first, then the crossing profile.

SuCri3ConnectJoint

Joint

V

Two profiles butt end to end.

SuCri3Connect3Corner

3 corner

Y

Three profiles meet at a node. Select the main profile first, then the other two.

SuCri3Connect4Corner

4 corner

K

Four profiles meet at a node. Select the main profile first, then the other three.

SuCri3ConnectParallel

Parallel

P

Two parallel profiles. Select the main profile first, then the parallel profile.

Step-by-step guide

  1. Determine the installation situation (e.g. profile butts against main profile = Collision, type T).
  2. Start the appropriate command and select the profiles in the specified order, the main profile first.
  3. Select the desired connection from the displayed list.
    Expected result: SuCri places the connection with the components from the manufacturer's catalog.

Which extension provides which connections?

  • Each manufacturer extension comes with its own catalog. The connections are stored per manufacturer in the Module 3 installation folder under Resources\VendorCatalogues\<Hersteller>.
  • SuCri only offers connections from the active manufacturer's catalog that match the selected profile combination.
  • You can get a complete overview of the connections via the index data sheets (see 7.5.8. Where can I see which Connections are available? (Advance Steel)).

Troubleshooting

  • No connection offered: Check the type and selection order and whether the profile is supported in the active manufacturer's catalog. For unsupported profiles, see 7.5.7. How can I work with profiles that are not supported.
  • Connection no longer fits after a profile change: Run SuCri3ValidateConnections ("Validate connections"); SuCri offers valid replacement connections.