Skip to Content

7.5.3. Storage location for your own special parts

Updated on 07/09/2026

On this page

    In this article you will learn how to manage your own special parts for SuCri Module 3 in Advance Steel. SuCri loads components exclusively from the Resources\VendorCatalogues folder in the installation folder (bundle folder) SuCri_Module3.bundle; there is no freely selectable external component path. To ensure that your special parts survive an update, also back them up outside the bundle folder.

    Prerequisites

    • SuCri Module 3 is installed for Advance Steel.
    • You have write permissions for the installation folder and for a backup folder.

    Step-by-step instructions

    1. Create a backup folder: Create a central folder outside the SuCri installation, for example on a network drive.
      Example: D:\Plant3D\CustomParts\
    2. Back up special parts: Keep the originals of your own special parts there, in the same folder structure as under Resources\VendorCatalogues\<Hersteller>.
    3. Import special parts: Copy the special parts into the matching manufacturer folder under Resources\VendorCatalogues\<Hersteller> and run SuCri3ReloadData ("Reload Vendor Data").
      Expected result: SuCri finds and uses your special parts.
    4. Restore after updates: The bundle folder is overwritten during updates or reinstallations. Afterwards, import your special parts again from the backup folder.

    Important notes

    • Safety: Your own customizations that exist only in the bundle folder are lost during updates or reinstallations.
    • No external search path: The backup folder is not read by SuCri. It only serves to keep your components across versions.
    • Best practice: Use consistent naming for the subfolders in the backup folder to keep things clear in large projects.

    Troubleshooting

    • Special parts are not found: Check whether the files are located in the correct manufacturer folder under Resources\VendorCatalogues, and run SuCri3ReloadData.
    • Special parts are only displayed as a frame: Run SuCri3FixSpecialPartDisplay ("Fix part display"). The command relinks special parts displayed as bounding boxes to their block definition.
    • Missing permissions: Make sure that no Windows restrictions block write access to the installation folder.

    Related articles

    Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.

    Still a question open?

    Write to us, we answer within 24 hours on business days.

    Request a consultation