8.3.6. Turbo Tools do not place any components
On this page
In this article you learn why the TurboTools may not suggest or place any components and how you can fix this behavior. A correctly configured working environment is a prerequisite for the flawless functioning of the automations.
Prerequisites
- An open AutoCAD Plant 3D project.
- Installed and licensed TurboTools.
Step-by-step guide
- Actively select the pipe class: In the Plant 3D user interface, select the desired pipe class that contains the required components.
- Check the pipe class: Make sure that the active pipe class actually contains the relevant elements (e.g. supports or valves). Extend the pipe class via the Spec Editor if necessary.
- Run TurboTools again: Restart the TurboTools only after the successful selection of the pipe class.
Expected result: The matching components from the active pipe class are now displayed in the tool selection of the TurboTools and can be placed in the model.
Important notes
- TurboTools check the active pipe class stored in the project in order to filter the available components.
- In projects with many pipe classes, use a clear naming convention to rule out mix-ups.
- If the tool selection remains empty, this is almost always an indication of a missing or incomplete pipe class.
Troubleshooting
If no components appear despite an active pipe class:
- Check whether the components in the pipe class are available for the current nominal size (Size).
- Make sure the pipe class is correctly linked in the Project Manager and is not write-protected or damaged.