4.3.5. Reload SuCri resources (SuCri3ReloadData)
On this page
Overview
With Reload SuCri resources, you apply changed manufacturer data and Module 3 settings without having to restart Plant 3D™. SuCri clears its caches and reads the manufacturer catalogs from the hard disk again.
Important: You actually only need this command if you do not want to close Advance Steel™ or Plant 3D™. On a restart, the SuCri resources are loaded anyway.
Where can I find the function?
In the Module 3 window under Quick Access > Reload Vendor Data, with Module 3 pinned to the tool palette in the Update group under Reload Vendor Data, or via the command line with SuCri3ReloadData.
Plant 3D™ command
Property | Value |
Command | SuCri3ReloadData |
Module 3 window | Quick Access > Reload Vendor Data |
Tool palette | Module 3 > Update > Reload Vendor Data |
Keyboard shortcut | No default shortcut |
From version | SuCri 25.1.1.1 |
Video: Reload SuCri resources in practice
How it works in detail
The command runs without any further prompt and performs three steps:
- The caches for components and connection data are cleared.
- The Module 3 settings are read again from the
sucri3_settings.jsonfile. This also applies changes that were made directly in this file. - The manufacturer catalogs are read in again from the
VendorCataloguesfolder in the Module 3 resource folder.
After that, all further Module 3 commands work with the newly loaded state. The connection dialog (SuCri3ShowSelectConnection) also reloads the manufacturer data when it is opened.
Application examples
Example 1: Importing new manufacturer data
You have replaced the Module 3 folders under the Application Plugins with a newer version. Then run SuCri3ReloadData so that Plant 3D™ works with the new data without a restart.
Example 2: Adapting components to new data
After reloading, you bring components and connections that have already been placed up to date with SuCri3BatchUpdateBlocks or SuCri3BatchUpdateConnections.
Tips and best practices
- Restart as an alternative: If you are restarting Advance Steel™ or Plant 3D™ anyway, the command is not necessary. The resources are loaded automatically at startup.
- Keep to the order: First replace the files, then run the command. Otherwise, the old state is loaded again.
- Existing components remain unchanged: Reloading does not change anything in the drawing. The update commands are responsible for components and connections that have already been placed.
Troubleshooting
- New components do not appear: Check whether the new files are in the correct folder of the installed plugin, and run the command again.
- Command does not respond: The command requires a valid license for Module 3.
Related articles
- Module 3 (P3D), overview of all functions of Module 3 in Plant 3D™.
- Installing Module 3 (P3D), installation of the module and storage of the manufacturer data.
Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.