8.3.7. No suitable support found in TurboTools
On this page
Learn how to solve problems with the placement of pipe supports using TurboTools. Check the geometry, adjust the pipe and choose alternative fastenings. Recommendations for use in tight installation situations are also provided.
Problem description
When using TurboTools for the placement of pipe supports, it can happen that no suitable support is proposed or displayed.
Cause
This behavior occurs when the distance to the steel structure is too small, or the outer diameter of the pipe does not fit into the range.
- In such cases, no suitable supports (e.g. pipe clamps) can be selected automatically.
- TurboTools searches the catalog for possible combinations but does not find any components that fit sensibly into the existing geometry.
Solution
- Check geometry
Measure the distance between the pipe and the steel structure.
Make sure there is enough space for the planned fastening.
- Adjust pipe
If possible, change the position or height of the pipe so that fastening systems have space.
- Choose alternative fastening
If no standard clamping system fits, select or place another type of fastening manually (e.g. via secondary steel).
- Check catalog
Make sure that the suitable fastening elements are present and activated in the catalog used.
- Check steel construction catalog
Make sure that the profile you want to connect to is also present in the steel construction catalog.
Recommendation
- In tight installation situations, check in advance whether a fastening system can technically be placed at all.
- For special cases: place fastenings manually or add them through individual adjustments in the catalog.
Also check the command line in Plant3D, there you get information about how many mm you have to move the pipe so that your support is proposed. Also check the command line in Plant3D to get information about how many millimeters you have to move the pipe so that the support is proposed.