11.1. Current version, Release notes for SuCri
On this page
11.1. Current version: SuCri Build 26.0.1.0
Released on 11/10/2026. The version number applies to all SuCri modules and is shown in the footer of every SuCri interface. You can find older release notes under Previous versions.
At a glance
- New Module 5 for secondary steel typicals.
- New Settings page on the dashboards and a shared SuCri Settings window with an English/German language switch. All settings can be imported from and exported to Excel.
- New validation of supports (Module 2) and connections (Module 3), each with repair.
- Module 3: favourite parts, Connect all, end caps for open member ends, Flip, and new Hilti MQ connections.
- Module 4: identical SUs combined into one drawing, BOM tables keep their spacing, plate details from a detail library.
- Supports Autodesk Plant 3D 2027 and Autodesk Advance Steel 2027. Modules 1 to 4 support Plant 3D (and Module 3 also Advance Steel) 2024 to 2027, Module 5 Plant 3D 2025 to 2027. Versions 2022 and 2023 are no longer supported, in line with Autodesk, which no longer supports them either. SuCri may still run there, but we no longer provide help or fixes for them.
General
Enhancements
- Upgraded the 2026 products to .NET 10.
- Supports Autodesk Plant 3D 2027 and Autodesk Advance Steel 2027.
- New SuCri Settings window (
SuCriSettings, Settings button on the ribbon) with one tab per module and an English/German language switch. - Dashboards, palettes, tooltips, dialogs and command-line prompts of Modules 2 to 5 are available in English and German. The licence and support dialogs are now available in English and German as well.
- The Module 2, 3 and 4 dashboards can be pinned to a dockable SuCri tool palette.
- New Support Request dialog (
SuCriSendSupportRequest) replaces the e-mail and can attach the log and crash data. You can add your own files up to 10 MB in total. If the server cannot be reached, SuCri saves the request as a ZIP file that you send to the helpdesk. - New Manage SU numbers window (
SuCri2ManageSuNo,SuCri4ManageSuNo) lists the used, orphaned and unused SU numbers of the project, goes to a support and clears orphaned numbers. - ConnectionBuilder: new tool for creating connection definitions for Module 3 (
SuCriCBBuildConnection, Plant 3D 2025 to 2027).
Fixes
- Fixed dashboards appearing only in the taskbar or behind AutoCAD.
- The Properties palette no longer opens by itself when Plant 3D starts.
- Fixed the vendor logo not showing in the installer on some machines.
Module 2 (M2)
Enhancements
- New Settings page on the dashboard replaces the Excel setting converter. Every tab can import from and export to Excel.
- New Vendor Data editor (
SuCri2VendorData) for clamp, support, MTO and part data per vendor. - New setting Double profile reference position. The default is Middle of the 2 profiles.
- New support validation (
SuCri2ValidateSupports) with zoom, recheck and repair of findings. It also finds supports that sit on a pipe without being connected to it, and connects them on repair. - Switch Profile (
SuCri2SwitchProfileStructure) now also works on selected project drawings and writes an Excel report. - Export Primary Support (
SuCri2ExportPrimarySupport) now also works on selected project drawings. - Removed commands:
SuCri2LoadSetting,SuCri2LoadDynamicPropertyandSuCri2OpenLanguageMappingare replaced by the Settings page andSuCri2VendorData.SuCri2SwitchProfileStructureDrawingwas merged intoSuCri2SwitchProfileStructure,SuCri2ExportPrimarySupportForSelectionintoSuCri2ExportPrimarySupport.
Fixes
- Fixed Dynamic Properties reading data from the wrong spec row when several spec parts share a parameter set or SizeRecordId.
- Fixed wrong cut lengths of Sikla STABIL rods in Dynamic Properties and the MTO.
- Fixed crashes during the placement of multiple supports or clamps.
- Fixed the MTO steel item code always being "-" and the ItemCodeDelimiter setting being ignored.
- Fixed the Sikla MTO counting the MS 5P M12 S2 twice on some supports.
Module 3 (M3)
Enhancements
- Module 3 supports Plant 3D and Advance Steel 2024 to 2027. 2022 and 2023 are no longer supported.
- New connection validation (
SuCri3ValidateConnections), including members in xrefs. - Favourite parts: star parts per connection type in the connection dialog. Starred parts are listed first.
- Connect all: a starred part can be placed on every matching case of its connection type in the current drawing, the selected objects or (Plant 3D) the project drawings, with progress, Stop and one Undo step.
- New command
SuCri3CapOpenEndsplaces end caps on every open member end (current drawing or picked members; in Plant 3D also project drawings). - New right-click Flip for a connection: a free-end connection moves to the other member end, T, Y and K connections change side, and X, P and V connections swap the main and the second member.
- Faster connection creation and component switching (profile information is now cached). In Plant 3D, each member is read only once, which is faster on projects with network content.
- In Plant 3D, a single Undo now removes a whole connection.
- Free-end connections check the roll of the member, so parts that fit only one orientation (for example wall struts and brackets) are offered only in that orientation.
- Angled cut faces (for example a 45° brace cut flat onto the channel it meets) now also work in Advance Steel.
- New Hilti connections for the MQ channel system and new fixings for the MT base plates, see New Hilti connections (M3) below.
- The Advance Steel database patch now contains the Hilti MQ channel profiles, so the Hilti MQ connections also work in Advance Steel. Where the Hilti patch was applied before, run Clean and then Patch in the SuCri database patcher.
- Added the Sikla VMZ anchor (Anker VMZ) to the base plates 113071, 113072, 113097, 113098, 113420, 113421, 192788 and 192795.
- Added the Sikla PRO 46 IPE (X) connection and more Sikla parts on F 100/160 main profiles.
- Sikla TPH F 80/30 (116672, 116673) is now also offered where two TP F 80/30 profiles cross.
Fixes
- Fixed special parts being displayed as a bounding box (Advance Steel).
SuCri3FixSpecialPartDisplayrepairs existing drawings. - Plant 3D no longer shows the proxy information dialog for Module 3 parts.
- Fixed updating, deleting and copying connections in Plant 3D (cut profiles not restored, other connections changed).
- Fixed crashes when switching the part of a connection and after a failed part placement.
- Fixed a Plant 3D crash (acgsf.dll) on the next full redraw after connection work in drawings that already contain parts.
- Fixed the wrong connection being used when cutting.
- Fixed a duplicate cap for Sikla end cap (ADK) connections.
- Cutting, lengthening and restoring a member keep the cut-back or cut face at its other end. Free-end members are no longer shifted by 9 mm instead of being cut, and deleting a connection restores the member to its original length.
SuCri3BatchUpdateBlocksno longer fails on every block in Plant 3D.SuCri3BatchUpdateConnectionsno longer deletes or misplaces copied connections.- Copying a connection with an anchor group places the anchor chosen for that group.
- Connections on single channels in Plant 3D no longer sit half a channel width off the member axis.
- 90° corner brackets (for example Sikla EV CC 41, Hilti MQW and MT-C) are no longer offered on members that do not meet at 90°. They failed in Plant 3D and were drawn sheared in Advance Steel.
- Fixed Hilti MT T-connectors (MT-C-GSP T A, MT-C-GLP T) overlapping the branch member by 25 mm when an MT-80 or MT-100 main member is turned by 90°.
SuCri3ValidateProfileLengthnow also runs in Advance Steel.- The Advance Steel database patcher no longer fails after SuCri entries were edited in the Management Tools, or on databases with customer entries that use text keys (for example model roles).
Module 4 (M4)
Enhancements
- Settings are now edited on the dashboard Settings page. The
SuCri4LoadSettingcommand was removed. - New setting Linetype scale (LTSCALE) with Auto and No change.
- Create drawings per SU can combine identical SUs into one drawing. The SU window stays open while you work, every SU has a zoom button that highlights it in the model, and the new setting Identical SU tolerance (mm) (default 1 mm) sets how far identical SUs may differ.
- New setting Keep BOM table spacing from template: BOM tables that grow push the tables below them, so the template spacing is kept and the tables no longer overlap.
- Improved placement of the BOM balloons (position numbers).
- Plate details from a detail library drawing are placed in the detail area of the ortho drawing.
SuCri4DetailLibrarysets the library and the part property that selects the detail. - Ortho views can be updated after the Module 5 typical they show was edited or replaced.
- Module 4 commands stop with a warning when they are run in the wrong drawing (3D model instead of ortho drawing, or the other way round).
Fixes
- A drawing that fails during ortho generation no longer aborts the whole batch; the remaining supports are still generated.
- Hidden draw areas are now applied reliably.
- Fixed the hidden line mode Hidden lines in all views but not Layout plan.
- Fixed hidden lines coming out solid on templates with PSLTSCALE = 1.
- A locked header text layer no longer makes ortho generation fail.
- Fixed Auto Views stopping with an eNullPtr error before dimensions and annotations were placed.
- "Model to drawing properties" are now written to the ortho drawing.
- Update View no longer erases the new BOM balloons of the last updated view (for example when only the iso view is updated).
Module 5 (M5)
- New module: Module 5 creates secondary steel typicals for Sikla, MPSS and Hilti. With
SuCri5CreateSecondarySteelFromTemplateyou create secondary steel as a typical from a template, withSuCri5DesignSecondarySteelTemplateyou open the Template Designer, in which you design your own templates. Module 5 runs in Plant 3D 2025 to 2027.
New Hilti connections (M3)
Hilti parts added to Module 3 in this release. Article numbers without a prefix are the galvanised standard; F = hot-dip galvanised, R = stainless steel A4.
MQ channel system (all new)
| Hilti product | Part | Article numbers | Connection | Anchors / fixings |
|---|---|---|---|---|
| MQB-41, MQB-82 | Channel clamp | 369668, 369671; F: 304183, 304186; R: 304061, 304063 | Crossing (X) | - |
| MQK-21 D/300, /450, /600 | Bracket | 369617, 369618, 369619 | Free end (I) | HST3 M12x115, HST2 M12x105, HUS4-H 10x70 / 10x80 / 10x100, HAS-U M12x160 with HIT-RE 500 |
| MQK-SL (long), MQK-SK (short) | Angle strut | 369621, 369622; F: 304128, 304129; R: 304010, 304011 | Free end (I), Collision (T) on a wall channel | HST2 M12x105, HUS4-H 10x70 |
| MQP-1/1, MQP-1/3 | Channel base | 369646, 369647; F: 304161, 304162 | Free end (I) | MQP-1/1: HST2 M12x105, HUS4-H 10x70; MQP-1/3: HST4 M8x95 |
| MQP-2/3 | Channel base | 369648; F: 304163 | Free end (I) | HST4 M8x95 |
| MQP-21-72 | Channel base | 369651; F: 304165; R: 304047 | Free end (I) | HST2 M12x105, HUS4-H 10x70 |
| MQP-41, MQP-41-CP | Channel base | 2141927, 2184852 | Free end (I) | HST4 M8x95 |
| MQP-45 | Channel base 45° | 369649; F: 304164 | Free end (I) | HST2 M12x105, HUS4-H 10x70 |
| MQP-82 | Channel base | 369652; F: 304166; R: 304048 | Free end (I) | HST2 M12x105, HUS4-H 10x70 |
| MQP-G 45°, MQP-FG 44° | Hinged channel base | 369654, 284240; F: 304168 | Free end (I) | HST2 M12x105, HUS4-H 10x70 |
| MQP-L-6/2 | Channel base | 2141928 | Free end (I) | HST4 M8x95 |
| MQP-E | Wall bracket | 387735 | Free end (I) | HST2 M12x105, HUS4-H 10x70 |
| MQV-2/2 D-14 | Channel base | 369639; F: 304151; R: 304033 | Free end (I) | HST2 M12x105, HUS4-H 10x70 |
| MV-LDP-L 290x290 (single, set) | Load distribution plate | 2174558, 2174559 | Free end (I) | - |
| MQZ-E21, MQZ-E41 | Channel end cap | 370598, 369685 | Free end (I) | - |
| MQT-21-41, MQT-41-82, MQT-52-82-R | Beam clamp | 369675, 369676; F: 304190, 304191; R: 304067, 304068 | Crossing (X) | - |
| MQT-41, MQT-U | Beam clamp | 286107, 2115454 | Crossing (X) | - |
| MQV-12 | Channel connector | 369643; F: 304155; R: 304037 | Joint (V) | - |
| MQV-41 | Channel connector | 286101 | Joint (V) | - |
| MQV-P4 | Channel connector | 369644; F: 304156 | Joint (V) | - |
| MQV-T | Channel connector | 369645; F: 304157 | Collision (T) | - |
| MQV-2/2 D, MQV-3/2 D | Channel connector | 369638, 369640; F: 304150, 304152; R: 304032, 304034 | Collision (T) | - |
| MQW-2 | Angle connector | F: 304171; R: 304051 | Collision (T) | - |
| MQW-3, MQW-4, MQW-8/90 | Angle connector | 369656, 369658, 369659; F: 304172, 304174, 304175; R: 304052, 304054, 304055 | Collision (T) | - |
| MQW-2/45, MQW-3/45, MQW-3/135, MQW-8/45 | Angle connector | 369662, 369657, 369663, 369660; F: 304178, 304173, 304176; R: 304053, 304056 | Collision (T) | - |
| MQW-H2, MQW-H2-CP | Angle connector | 2141929, 2184851 | Collision (T) | - |
| MQW-L-1/1, MQW-L-2/1 | Angle connector | 2142020, 2142021 | Collision (T) | - |
| MQW-P2, MQW-Q2 | Angle connector | 369661, 369655; F: 304177 | Collision (T) | - |
| MQW-S/1, MQW-S/2 | Angle bracket | 369664, 369665; F: 304180, 304181; R: 304058, 304059 | Collision (T) | - |
| MQS-W Set | Seismic angle connector | 2330879 | Collision (T) | - |
MT system (new fixings for existing parts)
| Hilti product | Part | Article numbers | Connection | Anchors / fixings |
|---|---|---|---|---|
| MT-B-GL O4 | Base plate | 2272103 | Free end (I) | New: HUS4-HR 10x115, HUS4-HR 14x120 |
| MT-B-GL O4C | Base plate | 2343282 | Collision (T) on a steel beam | New: X-BT-MR M10, F-BT-MR M10 |
| MT-B-GS T, MT-B-GS O4U | Base plate | 2272100, 2272101 | Free end (I), Collision (T) on a steel beam | New: HUS4-HR 10x115, X-BT-MR M10 |
| MT-B-GXL O4 | Base plate | 2272104 | Free end (I) | New: HST3-R M16x135, HUS4-HR 10x115 |
| MT-B-GXL S1, S2, S3 | Base plate | 2272106, 2272107, 2272108 | Collision (T) on a steel beam | New: MI-SGC-M16 beam clamps; S1 also F-BT-MR M10 |
| MT-C-GSP T A | T connector | 2332785 | Collision (T) | Now also MT-70 with MT-80 |
Related articles
Copyright © 2026 by IntegaDesign GmbH. All Rights Reserved.